Co-reporter:Qisheng Zhong, Lingling Shen, Jiaqi Liu, Dianbao Yu, Siming Li, Jinting Yao, Song Zhan, Taohong Huang, Yuki Hashi, Shin-ichi Kawano, Zhaofeng Liu, Ting Zhou
Journal of Chromatography A 2016 Volume 1442() pp:53-61
Publication Date(Web):15 April 2016
DOI:10.1016/j.chroma.2016.03.010
•A novel sample injection technique PD-LVI for UHPLC–MS/MS was developed.•The features and mechanism of PD-LVI were systematically investigated.•The feasibility was demonstrated by analyzing 24 pesticides residues in cabbages.•PD-LVI could be extended to other LC system without extra complicated accessories.Pre-column dilution large volume injection (PD-LVI), a novel sample injection technique for reverse phase ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC–MS/MS), was developed in this study. The PD-LVI UHPLC–MS/MS system was designed by slightly modifying the commercial UHPLC–MS/MS equipment with a mixer chamber. During the procedure of PD-LVI, sample solution of 200 μL was directly carried by the organic mobile phase to the mixer and diluted with the aqueous mobile phase. After the mixture was introduced to the UHPLC column in a mobile phase of acetonitrile-water (15/85, v/v), the target analytes were stacked on the head of the column until following separation. Using QuEChERS extraction, no additional steps such as solvent evaporation or residue redissolution were needed before injection. The features of PD-LVI UHPLC–MS/MS system were systematically investigated, including the injection volume, the mixer volume, the precondition time and the gradient elution. The efficiency of this approach was demonstrated by direct analysis of 24 pesticides in cabbages. Under the optimized conditions, low limits of detection (0.00074–0.8 ng/kg) were obtained. The recoveries were in the range of 63.3–109% with relative standard deviations less than 8.1%. Compared with common UHPLC–MS/MS technique, PD-LVI UHPLC–MS/MS showed significant advantages such as excellent sensitivity and reliability. The mechanism of PD-LVI was demonstrated to be based on the column-head stacking effect with pre-column dilution. Based on the results, PD-LVI as a simple and effective sample injection technique of reverse phase UHPLC–MS/MS for the analysis of trace analytes in complex samples showed a great promising prospect.
Co-reporter:Qisheng Zhong;Lingling Shen;Jiaqi Liu;Dianbao Yu;Simin Li;Zhiru Li;Jinting Yao;Taohong Huang;Shin-ichi Kawano;Yuki Hashi
Journal of Separation Science 2016 Volume 39( Issue 11) pp:2129-2137
Publication Date(Web):
DOI:10.1002/jssc.201600129
An automatic on-line solid-phase extraction with ultra-high performance liquid chromatography and tandem mass spectrometry method was developed for the simultaneous determination of ten antipsychotics in human plasma. The plasma sample after filtration was injected directly into the system without any pretreatment. A Shim-pack MAYI-C8 (G) column was used as a solid-phase extraction column, and all the analytes were separated on a Shim-pack XR-ODS III column with a mobile phase consisting of 0.1% v/v formic acid in water with 5 mM ammonium acetate and acetonitrile. The method features were systematically investigated, including extraction conditions, desorption conditions, the equilibration solution, the valve switching time, and the dilution for column-head stacking. Under the optimized conditions, the whole analysis procedure took only 10 min. The limits of quantitation were in the range of 0.00321–2.75 μg/L and the recoveries ranged from 75.9 to 122%. Compared with the off-line ultra-high performance liquid chromatography and the reported methods, this validated on-line method showed significant advantages such as minimal pretreatment, shortest analysis time, and highest sensitivity. The results indicated that this automatic on-line method was rapid, sensitive, and reliable for the determination of antipsychotics in plasma and could be extended to other target analytes in biological samples.
Co-reporter:Qisheng Zhong, Xiongxiong Qiu, Caiyong Lin, Lingling Shen, Yin Huo, Song Zhan, Jinting Yao, Taohong Huang, Shin-ichi Kawano, Yuki Hashi, Langtao Xiao, Ting Zhou
Journal of Chromatography A 2014 Volume 1359() pp:131-139
Publication Date(Web):12 September 2014
DOI:10.1016/j.chroma.2014.07.031
•An automatic versatile SPE-UHPLC–MS/MS system was developed.•The online system was realized by a dual-dilution strategy.•A post-column compensation mode for the matrix-effects evaluation was designed.•System feasibility was demonstrated by the analysis of 3 auxins from plant tissues.An automatic versatile system which integrated solid phase extraction (SPE) with ultra-high performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) was developed. Diverse commercial SPE columns can be used under an ambient pressure in this online system realized by a dual-dilution strategy. The first dilution enabled the direct injection of complex samples with minimal pretreatment, and the second dilution realized direct introduction of large volume of strong eluent into the UHPLC column without causing peak broadening or distortion. In addition, a post-column compensation mode was also designed for the matrix-effects evaluation. The features of the online system were systematically investigated, including the dilution effect, the capture of desorption solution, the column-head stacking effect and the system recovery. Compared with the offline UHPLC system, this online system showed significant advantages such as larger injection volume, higher sensitivity, shorter analysis time and better repeatability. The feasibility of the system was demonstrated by the direct analysis of three auxins from different plant tissues, including leaves of Dracaena sanderiana, buds and petals of Bauhinia. Under the optimized conditions, the whole analysis procedure took only 7 min. All the correlation coefficients were greater than 0.9987, the limits of detection and the limits of quantitation were in the range of 0.560–0.800 ng/g and 1.80–2.60 ng/g, respectively. The recoveries of the real samples ranged from 61.0 to 117%. Finally, the post-column compensation mode was applied and no matrix-effects were observed under the analysis conditions. The automatic versatile system was rapid, sensitive and reliable. We expect this system could be extended to other target analytes in complex samples utilizing diverse SPE columns.